You are here:

PowerEdge5 Edge Data Center

Enhanced Enterprise Micro Data Center with Full N+1 Redundancy
PowerEdge 5 is a 5-cabinet edge data center row engineered for mission-critical workloads in regional offices and industrial sites. It combines N+1 power and cooling redundancy, advanced DCIM, high-capacity rack space and premium containment in a compact footprint.
IT Load Capacity
25–40 kW

Redundancy
N+1 Power & Cooling

Footprint
4000 × 1200 mm

Description

PowerEdge 5 — Enhanced Enterprise Micro Data Center (25–40 kW)

PowerEdge 5 delivers substantial edge capacity with comprehensive N+1 redundancy for power and cooling.
Designed for mission-critical workloads, it provides premium containment, advanced monitoring and scalable rack space in a compact row format.

5 × 42–52U Cabinets
IT Load: 25–40 kW
Cooling: Up to 45 kW (N+1)
Power: 50 kVA (N+1)
Advanced DCIM + 32" HMI

Key Technical Facts

Cabinets
5 × 42–52U
Footprint
4000 × 1200 mm
Available Rack Units
160–200U
Weight (typ.)
~1400 kg (fully equipped)
Cooling
Up to 45 kW (N+1)
Power
50 kVA (N+1)

Final topology, runtime and cooling type are project-specific.

Documents

Go to Downloads

PowerEdge catalogue link is provided in the Downloads section.

Overview

PowerEdge 5 is designed for regional offices, manufacturing facilities and enterprise edge sites where uptime is critical.
The configuration supports full component redundancy for key systems, enabling continuous operation during maintenance or component failures.

Typical cabinet roles: Primary UPS & batteries, network core & security cluster, compute, storage/backup & expansion, secondary UPS & batteries.

Technical Specifications

Cabinets 5 × 42–52U (height configurable)
Cabinet Width 600 mm or 800 mm
Standard Footprint 4000 × 1200 mm
Weight (typ.) ~1400 kg (fully equipped)
IT Load Capacity 25–40 kW
Available Rack Units 160–200U (depending on configuration)
Cooling Capacity Up to 45 kW with N+1 redundancy
Power Capacity 50 kVA with N+1 redundancy (standard)
Management Advanced DCIM + 32" touch screen management interface
Fire Safety Comprehensive fire detection with FM200 suppression (typ.)

Model Matrix

Configuration Cabinets IT Load Cooling Power Monitoring Security
PowerEdge 5 5 25–40 kW In-row, N+1 N+1 Advanced DCIM Enhanced
Exact equipment mapping and redundancy scope are defined during the project engineering phase.

Options

Power & Runtime

Extended battery modules, maintenance bypass, generator connection panel (project-based).

Cooling & Containment

Redundant in-row cooling, pressure-controlled containment, higher-density support options.

Monitoring & DCIM

Advanced environmental sensor expansion, predictive analytics features, integration to BMS/DCIM.

Security

Enhanced physical security package, access control upgrades, CCTV-ready options.

Downloads

Catalogue is provided for general reference. Final configuration and BoQ are project-specific.

Description

PowerEdge 5 — Enhanced Enterprise Micro Data Center (25–40 kW)

PowerEdge 5 delivers substantial edge capacity with comprehensive N+1 redundancy for power and cooling.
Designed for mission-critical workloads, it provides premium containment, advanced monitoring and scalable rack space in a compact row format.

5 × 42–52U Cabinets
IT Load: 25–40 kW
Cooling: Up to 45 kW (N+1)
Power: 50 kVA (N+1)
Advanced DCIM + 32" HMI

Key Technical Facts

Cabinets
5 × 42–52U
Footprint
4000 × 1200 mm
Available Rack Units
160–200U
Weight (typ.)
~1400 kg (fully equipped)
Cooling
Up to 45 kW (N+1)
Power
50 kVA (N+1)

Final topology, runtime and cooling type are project-specific.

Documents

Go to Downloads

PowerEdge catalogue link is provided in the Downloads section.

Overview

PowerEdge 5 is designed for regional offices, manufacturing facilities and enterprise edge sites where uptime is critical.
The configuration supports full component redundancy for key systems, enabling continuous operation during maintenance or component failures.

Typical cabinet roles: Primary UPS & batteries, network core & security cluster, compute, storage/backup & expansion, secondary UPS & batteries.

Technical Specifications

Cabinets 5 × 42–52U (height configurable)
Cabinet Width 600 mm or 800 mm
Standard Footprint 4000 × 1200 mm
Weight (typ.) ~1400 kg (fully equipped)
IT Load Capacity 25–40 kW
Available Rack Units 160–200U (depending on configuration)
Cooling Capacity Up to 45 kW with N+1 redundancy
Power Capacity 50 kVA with N+1 redundancy (standard)
Management Advanced DCIM + 32" touch screen management interface
Fire Safety Comprehensive fire detection with FM200 suppression (typ.)

Model Matrix

Configuration Cabinets IT Load Cooling Power Monitoring Security
PowerEdge 5 5 25–40 kW In-row, N+1 N+1 Advanced DCIM Enhanced
Exact equipment mapping and redundancy scope are defined during the project engineering phase.

Options

Power & Runtime

Extended battery modules, maintenance bypass, generator connection panel (project-based).

Cooling & Containment

Redundant in-row cooling, pressure-controlled containment, higher-density support options.

Monitoring & DCIM

Advanced environmental sensor expansion, predictive analytics features, integration to BMS/DCIM.

Security

Enhanced physical security package, access control upgrades, CCTV-ready options.

Downloads

Catalogue is provided for general reference. Final configuration and BoQ are project-specific.