You are here:

HDCV Mid / Large Room Cooling 30 – 250kW

High-Capacity Chilled Water Cooling for Large Data Rooms (30–250 kW)
HDCV is a high-capacity chilled-water precision cooling solution designed for large IT environments with demanding sensible load.
The platform supports EC fan efficiency and can be supplied with single or dual cooling coil configurations for increased flexibility.
Cooling Range
30–250 kW

Technology
Chilled Water (CW)

Configuration
Downflow (Single/Dual Coil)

Description

HDCV – High Capacity Chilled Water Room Cooling (30–250 kW)

HDCV chilled-water precision cooling is intended for large data rooms requiring high sensible cooling capacity and stable 24/7 operation.
The system uses EC fan efficiency and supports downflow installation with single or dual coil configurations.

Chilled Water (CW)
30–250 kW Range
EC Fans
Downflow
Single / Dual Coil
BMS / Monitoring Ready

Key Technical Facts

Cooling Range
30–250 kW
Technology
Chilled Water (CW)
Fans
EC Fan Module
Installation
Downflow

Documents

Go to Downloads

Catalogue is listed in the Downloads section.

Overview

HDCV is built for high airflow and large coil surface to minimize pressure drops and support high sensible heat ratio applications.
The architecture supports efficient fan control, service access from the front, and common monitoring/alarm requirements for critical sites.

Technical Specifications (Summary)

Technology Chilled Water (CW)
Cooling Capacity 30–250 kW (model dependent)
Versions Downflow – Single Coil / Downflow – Dual Coil
Fans Radial EC fan technology (efficiency focused)
Controls Microprocessor control; BMS connectivity (protocol dependent)
Maintenance Full front accessibility

Model Matrix

Model selection is project-specific (airflow, coil selection, redundancy). Use the catalogue as a reference and contact Devis for sizing.

Options & Accessories

  • Dual power supply / changeover options (configuration dependent)
  • Energy metering / monitoring options (configuration dependent)
  • Floor pressurization / airflow accessories (site dependent)
  • Valves / flow meter options (hydraulic design dependent)

Downloads

Catalogue is hosted on devis.co.uk for reliable access and consistent performance.

Description

HDCV – High Capacity Chilled Water Room Cooling (30–250 kW)

HDCV chilled-water precision cooling is intended for large data rooms requiring high sensible cooling capacity and stable 24/7 operation.
The system uses EC fan efficiency and supports downflow installation with single or dual coil configurations.

Chilled Water (CW)
30–250 kW Range
EC Fans
Downflow
Single / Dual Coil
BMS / Monitoring Ready

Key Technical Facts

Cooling Range
30–250 kW
Technology
Chilled Water (CW)
Fans
EC Fan Module
Installation
Downflow

Documents

Go to Downloads

Catalogue is listed in the Downloads section.

Overview

HDCV is built for high airflow and large coil surface to minimize pressure drops and support high sensible heat ratio applications.
The architecture supports efficient fan control, service access from the front, and common monitoring/alarm requirements for critical sites.

Technical Specifications (Summary)

Technology Chilled Water (CW)
Cooling Capacity 30–250 kW (model dependent)
Versions Downflow – Single Coil / Downflow – Dual Coil
Fans Radial EC fan technology (efficiency focused)
Controls Microprocessor control; BMS connectivity (protocol dependent)
Maintenance Full front accessibility

Model Matrix

Model selection is project-specific (airflow, coil selection, redundancy). Use the catalogue as a reference and contact Devis for sizing.

Options & Accessories

  • Dual power supply / changeover options (configuration dependent)
  • Energy metering / monitoring options (configuration dependent)
  • Floor pressurization / airflow accessories (site dependent)
  • Valves / flow meter options (hydraulic design dependent)

Downloads